Bose ControlSpace Guía de instalación Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
9
The CC-16 zone controller has an 8-position DIP switch located on the back of the unit. The
DIP switches control addressing and termination settings.
DIP switch addresses
Up to fifteen CC-16s can be connected to an ESP-88 and each must have a unique
address. Use the DIP switches numbered 4, 5, 6 and 7 on the back of the unit to set the
address – 1 through 15. The addresses are in binary format. Refer to the illustration below
to locate binary addresses and the corresponding switch positions.
DIP Switch Settings
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 19 20

Comentarios a estos manuales

Sin comentarios